Pyronix KX15ED Grade 2 Dual Element PIR with selectable resistors
Features
-
- Dual element pyro-electric sensor
- 15m Volumetric detection coverage
- Selectable EOL (End Of Line) resistors
- Patented Independent Floating Thresholds (IFT)
- Adjustable sensitivity settings
- Automatic temperature compensation
- Tamper proof brackets included
- Sealed optics
- ABS plastics
Details
Features | Description |
15m Volumetric detector | 15m Volumetric detection coverage. Ideal for protection of rooms, offices etc. |
Selectable EOL resistors | The detectors incorporates selectable alarm resistor values of 6K8, 5K6, 4K7 &1K & tamper values of 5K6, 4K7, 2K2 and 1K catering for most control panels on the market. |
Selectable EOL resistors | The detectors incorporates selectable alarm resistor values of 6K8, 5K6, 4K7 &1K & tamper values of 5K6, 4K7, 2K2 and 1K catering for most control panels on the market. |
Patented Independent Floating Thresholds (IFT) | This technology patented by Pyronix allows the detector to respond to the environmental changes by automatically adjusting its levels of immunity to background disturbances. |
Adjustable sensitivity settings | Adjustable sensitivity settings for installations in a any environment. (High/Low) |
Automatic temperature compensation | When the product is used in a hot environment this technology automatically adjusts the detector’s sensitivity allowing it to maintain its range even when the background room temperature is almost equal to the external body temperature of 32c |
Tamper proof brackets | Supplied with both wall & ceiling mount brackets which provides access for up to two 8 core cables (Tamper kit optional) |
Sealed optics | Protects from possible infestation from insects, shields air movement in front of the pyro-electric sensor and protects against adverse reflections from inside the detector housing. |
ABS plastics | 3mm polished finish, reduces electrostatic interference on the PIR sensor. |
Technical Specification
ELECTRICAL | |
Operating voltage | 9-16VDC (12V nominal) |
Current consumption – no alarm | 11mA (12V nominal) |
Current consumption – alarm | 13mA (12V nominal) |
Relay | Solid state |
Relay output | 60VDC, 50mA Protected |
Tamper switch | 12V max, 50mA max |
RFI immunity to continuous wave (CW) 80-2000MHz | 10 V/m |
RFI immunity to amplitude modulation (AM) 80-2000MHz | 10 V/m |
RFI immunity to pulse modulation (PM) 80-2000MHz | 10 V/m |
OPERATING FEATURES | |
Detection speed | 0.3 – 3m/s |
Operating temperature | -30 |
Storage temperature | -40 |
Alarm period of | 2.5 seconds |
OPTICAL | |
White light filter | 6500 Lux |
Optics | Sealed |
Lens | 3 Dimensional |
Protection | Ultraviolet Light Filter |
MOUNTING | |
Optimum coverage height | 1.8-2.4m |